Title Comparative Analysis on the Distribution of Wind Pressure Coefficient in Glass Greenhouse according to the Shape and Slope of Roof
Authors Hwang Jin-Taik ; You Ki-Pyo ; Kim Young-Moon
Page pp.47-54
ISSN 12269107
Keywords Agricultural Facilities ; Wind Tunnel Test ; Wind Pressure Coefficient ; Glass Greenhouse
Abstract Because the current wind load standard is not suitable for agricultural facilities, it is necessary to establish a more adequate load standard for agricultural facilities. Thus, this study built models for venlo?type and wide?type glass greenhouses, and conducted wind pressure experiment according to the slope and shape of roof surface. Because there is no accurate standard for agricultural facilities, we compared the external pressure coefficients for gable?roofed structures and multiple?gable?roofed ones suggested in the Korea load standard (KBC-2009) with values obtained from the experiment. For wide?type glass greenhouses, the load standard was similar to the experimental value. For venlo?type glass greenhouses, however, while the load standard specified that a milder roof slope is more advantageous, the external pressure coefficient obtained from the experiment showed a more advantageous result when the slope was steeper.