Title Wind Response Monitoring of a Building with TMD
Authors Kim, Hong-Jin ; Choi, Sun-Young ; Jo, Seong-Woo ; Hwang, Jae-Seung ; Yu, Eun-Jong
Page pp.83-90
ISSN 12269107
Keywords Tuned Mass Damper ; Wind-induced Vibration ; System Identification ; Inverse Load Estimation
Abstract The wind response and performance of a tuned mass damper (TMD) are presented based on the system identification and the inverse wind load estimation. The TMD was installed on a 39-story, 184.6m steel building located in Incheon, Korea with a monitoring system consisting of an anemometer, accelerometers, and internet-based data logging system. On Sep. 2, 2010, the building experienced the Kompasu Typhoon, in which the peak wind speed, measured by an anemometer installed on the roof floor, was 49.7 m/s. In order to analyze the behavior of the building during the typhoon, the dynamic properties of building and TMD are identified from the measured responses. The modal wind load is then inversely estimated from the TMD and building accelerations using a Kalman filter, and the vibration reduction performance of the TMD is evaluated.