Title |
An Experimental Study on the Fire-Resistant Performance of Eco-Friendly Extruding Concrete Panel |
Authors |
Song, Tae-Hyeob ; Park, Ji-Sun ; Lee, Sea-Hyun |
Keywords |
Eco-friendly ; Extruding Panel ; Fire Resistant Performance |
Abstract |
The fire resistance performance of eco-friendly extruding concrete panel was analyzed experimentally. Two kinds of experiments were performed. First experiment, simple test, was considered four types of small size(500 x 500 mm) extruding concrete panel with 30 or 50 mm section thickness as well as heated by small furnace. And then from the pre-test results, second experiment was performed real size(3,000 x 3,000 mm) extruding concrete panel with two kinds of section types. One was composed single panel with 50 mm section thickness and the other was composed double 50 mm section thickness panel with air space. And all testing procedures including set-up test equipments and measuring devices were followed according to the KS F 2257-1, 8. From the second test results, it was found that the fire-resistance performance of all specimens in the second test were satisfied the fire-resistance standard of light weight wall. |