Title |
A Study on the Structural Performance of the Building Exterior PanelUsing the Moving Clips |
Authors |
Kwak, Eui-Shin ; Ki, Chang-Gun ; Lee, Sang-Ho ; Shon, Su-Deok ; Lee, Seung-Jae |
DOI |
https://doi.org/10.5659/JAIK_SC.2017.33.12.29 |
Keywords |
Moving Clips ; Exterior Panel ; Following Capacity ; Non-structural elements ; Drift angle ; Shake table test |
Abstract |
A recent global trend in the increase of earthquake-related disasters has become so frequent as to cause various damages to a wide range of mid- to high-rise buildings. Particularly, more attention is being paid to the effect of horizontal load in high-rise buildings not only on the key structural elements of the structures, but also on the possibility of the secondary damages to them due to the failure of exterior panels, which are non-structural elements, but such damages are difficult to cope with as they may be caused by unexpected changes. The present study examined exterior panels using moving clips to prevent such secondary damages on the non-structural elements and analyzed the structural performance of these exterior panels through the finite element analysis and the shaking table test. The analysis results showed that the exterior panels using moving clips satisfied the structural performance against the allowable story drift of KBC2009 and the safety of the exterior panels was verified by the shake table test. |