Title |
Performance Analysis of Heating Nonslip using Solar Power Energy |
Authors |
Moon, Jong Wook ; Choe, Jae Won ; Yun, Seok Heon |
DOI |
https://doi.org/10.5659/JAIK_SC.2018.34.6.55 |
Keywords |
Heating Nonslip ; Solar Power ; Performance Analysis |
Abstract |
This study aims to analyze the performance of Heated-nonslip using renewable energy to prevent nonslip freezing during winter. For this purpose, power generation system and congratulatory devices using solar energy are designed, and it is designed to provide regular electricity to heat up nonslip through Electrical storage system(ESS). In this study, It is intended to analyze the level of electrical energy suitable for nonslip using 24V or 48V, and to measure the temperature changes and temperature distribution according to the location of the test object. As a result of the experiment, nonslip's frame temperature was measured at ? 7.5 ~ -5 ℃ on average, and ?1 ~ -2 ℃ on the heating cable during the supply of 24V and this could not be the solution for defrosting freezing nonslip in the winter. As a result of heating nonslip by supplying 48V with an electrical power of 8W, the temperature of the nonslip was shown to be between 5 ℃ and 11 ℃ to 13 ℃. Even if the power supply was switched on and off every minute, the temperature did not drop below 4 ℃ and the frozen ice melted on the nonslip without freezing. |