Title |
Annual Intensities (2016?2017) Analysis of Energy Use and CO2 Emission by End Use based on Measurements of Sample Apartment Units |
Authors |
Jin, Hye-Sun ; Lim, Han-Young ; Lee, Soo-Jin ; Kim, Sung-Im ; Lim, Jae-Han ; Song, Seung-Yeong |
DOI |
https://doi.org/10.5659/JAIK_SC.2018.34.7.43 |
Keywords |
Apartment unit ; Measurement ; Site Energy Use Intensity (EUI) by End Use ; Primary EUI by End Use ; CO2 Emission Intensity by End Use |
Abstract |
In this study, annual site and primary energy use intensities (EUIs) and CO2 emission intensities (CEIs) per area by end use were estimated based on the measurement data from June 2016 to May 2017 of 50 sample apartment units in Seoul. In addition, estimated site EUIs by end use were compared to the U.S. Residential Energy Consumption Survey (RECS) 2009 data. Site EUIs by end use were found to be in the order of heating > electric appliance > domestic hot water > cooking > lighting > cooling > air movement. In the case of primary EUIs and CEIs by end use, electric appliance was found to be the largest. As results of comparison with the RECS 2009 data, it was found that site EUIs were very similar for heating, domestic hot water and electric appliance, etc., but slightly different for cooling. The number of sample apartment units will continue to increase until 2020 (total number of samples 200) and intensities data by end use will be continuously updated through continuous collection of measurement data. |