Title |
Flexural Response of Negative Moment Region of Hybrid Prestressed Precast Concrete (HPPC) System |
Authors |
Choi, Seung-Ho ; Hwang, Jin-Ha ; Heo, InWook ; Kim, Kang Su ; Woo, Woon-Taek |
DOI |
https://doi.org/10.5659/JAIK_SC.2018.34.10.3 |
Keywords |
Prestressed cocnrete ; Precast concrete ; Post-tension ; Joint ; Flexure |
Abstract |
Hybrid Prestressed Precast Concrete System (HPPC system) is a newly developed frame system that can improve the performance of precast concrete (PC) joints by post-tensioning. In particular, the details proposed in this study can reduce the lifting weight of the PC members and eliminate problems caused by cracks in the joints that occur under service loads. This study performed an evaluation on the negative moment performance of full-scaled HPPC girders. The test specimens were cast with or without slabs, with bonded or unbonded tendons, and had different post-tensioned lengths in tensile section. The test results showed that the specimens with slabs had significantly higher stiffness and strength than those without slabs. There were no differences in the flexural behavior between those with bonded or unbonded tendons, and between those with short or long post-tensioned lengths in the negative moment region. |