Title |
Rotational Stiffness of Connection in Multi-span Vinyl Greenhouse |
Authors |
Kim, Min-Sun ; Choi, Ki-Sun ; Shin, Ji-Uk |
DOI |
https://doi.org/10.5659/JAIK_SC.2018.34.12.3 |
Keywords |
Multi-span Vinyl Greenhouse ; Connection ; Rotational Stiffness |
Abstract |
Recently, severe damage to domestic horticultural structures is frequently observed due to extreme climate effects. To minimize the structures' damage, a study on the structural stability of multi-span vinyl greenhouses is needed. This paper presents to measure the rotational stiffness of different connectors to improve the design capacities of the specification. The paper investigated fourteen types of the different connectors, which was commonly used in the multi-span greenhouses, and three different types of the connectors predicted to be under moment-connection were selected: i) T-clamp, ii) U-clamp, iii) C-clamp. Static loading tests for three different connectors were performed to measure the rotational stiffness. Additionally, the boundary condition for the structural design was proposed based on the experimental results of the rotational stiffness. One of three connectors, C-clamp had larger rotational stiffness than other connectors, and the experimental results presented the three connectors had boundary conditions; i) T-clamp was pinned-connection, ii) U-clamp was semi-rigid connection, iii) C-clamp was semi-rigid connection. |