Authors Hwang, Jong-Kook ; Kwon, Yang-Hee ; Bae, Dong-Hun
DOI https://doi.org/10.5659/JAIK_SC.2019.35.3.11
Page pp.11-18
ISSN 1226-9107
Keywords Traditional Wooden Structures ; Length of shear wall ; Traditional Wall Frame ; Wooden Shear Wall
Abstract The purpose of this study was to estimate the resistance capacity of a traditional wooden house with shear walls made of wood panel. In order to achieve the purpose of the study, the load - displacement test was carried out and the resistance moment values ??of the shear walls were proposed. The shear walls were made by placing studs with a nominal dimension of 38 mm × 89 mm at intervals of 600 mm, and attaching 12 mm thick plywood with 8-d size pegs at intervals of 150 mm. The type of traditional building wall was classified and showed the moment resistance ability of each wall type. This value is expressed as a proportional value divided by the moment resisting capacity of the standard size shear walls not divided into the divided small frames. Although some frames have proportional values ??larger than 1.0 even though they have openings, most of them show values ??smaller than 1.0. Also, even without the openings, it showed a smaller value than 1, such as 0.84 and 0.67.