Title A Study on Limit Deformation to Out-of-Plan Direction of Wall with Internal Structural Element in Traditional Wooden Walls
Authors 황종국(Hwang, Jong-Kook) ; 권양희(Kwon, Yang-Hee)
DOI https://doi.org/10.5659/JAIK.2020.36.9.131
Page pp.131-138
ISSN 2733-6247
Keywords "Traditional Wooden Structure; Wall; Muryangsujeon; Limit drift ratio; Elastic wave; fitting; Deformation; Out of plan direction"
Abstract A study was conducted to determine the limit drift ratio of a traditional wooden structure wall. One of the national treasure traditional wooden buildings, the deformation is proceeding from the right side wall of Muyangsujeon to the out-of-plane direction. By this reason, the limit drift ratio was determined by selecting the wall of Muyangsujeon as an example of this study. Although there is a limitation that the Muyangsujeon wall does not mean all walls of the traditional wooden structures, the purpose was to provide basic data to choice a reasonable determination in the case of a Traditional Wall constructed in a similar way to the Muyangsujeon wall. In the case of historical buildings, it is often difficult to know exactly what is needed, so this study tried to determine the limit drift ratio of a traditional wall by using the minimum information available such as wall deformation and wall size. It has been confirmed that in the case of a traditional wall with studs inside, such as the right wall of Muyangsujeon wall, an unstable condition may occur when the limit drift ratio of the point in the center of the wall divided by the height of the wall divided by the wall height approaches 3.1%.