Title |
Experimental Exploration of 3-Hour Fire Resistance in Beam-to-Beam Combination Structures within Steel Structure Modular Units |
Authors |
장활제(Jang, Hwal-Je) ; 송재은(Song, Jae-Eun) ; 김양범(Kim, Yang-Bum) ; 김경수(Kim, Kyung-Su) ; 안용한(Ahn, Yong-Han) |
DOI |
https://doi.org/10.5659/JAIK.2024.40.2.261 |
Keywords |
철골조, 모듈러 유닛, 보, 보-보 결합 구조체, 3시간 내화성능 |
Abstract |
This study aims to assess the 3-hour fire resistance capabilities of a beam-to-beam combination structure, mirroring the on-site assembly
features of the modular construction method. A specific detail for the 3-hour fire resistance of the beam-to-beam combination structure was
put forth, followed by a non-load heating test utilizing a horizontal heating furnace. In this proposed detail, fireproof gypsum boards cover
the beams of individual modular units, the linear joint between on-site installed beams is filled with fireproof insulation or ceramic wool, and
a fireproof sealant is applied for non-flammability assurance. The results from two rounds of 3-hour fireproof tests demonstrated satisfactory
fireproof performance. |