Title Wind Resistance Performance Evaluation of Cable-Concrete Joint Facade System
Authors 박현수(Park, Hyun-Soo) ; 마종운(Ma, Jong-Woon)
DOI https://doi.org/10.5659/JAIK.2025.41.2.311
Page pp.311-317
ISSN 2733-6247
Keywords Cable-Type Curtain Wall System; Structural Performance; Cable-Concrete Joint; Initial Pre-Tension; Facade System
Abstract In this study, a cable-concrete joint was proposed so that the cable-type curtain wall system can be applied to reinforced concrete structures, and its performance was verified through structural experiments. As a result of the experiment, it was confirmed that the performance of the cable-concrete joint proposed in this study exceeded the wind load design strength in the metropolitan area, and that it could be applied to the facade of reinforced concrete high-rise buildings. However, it was confirmed that the cable-concrete joint design requires consideration of the cable initial pre-tension according to the facade load conditions.