Title |
Wind Resistance Performance Evaluation of Cable-Concrete Joint Facade System |
Authors |
박현수(Park, Hyun-Soo) ; 마종운(Ma, Jong-Woon) |
DOI |
https://doi.org/10.5659/JAIK.2025.41.2.311 |
Keywords |
Cable-Type Curtain Wall System; Structural Performance; Cable-Concrete Joint; Initial Pre-Tension; Facade System |
Abstract |
In this study, a cable-concrete joint was proposed so that the cable-type curtain wall system can be applied to reinforced concrete structures,
and its performance was verified through structural experiments. As a result of the experiment, it was confirmed that the performance of the
cable-concrete joint proposed in this study exceeded the wind load design strength in the metropolitan area, and that it could be applied to
the facade of reinforced concrete high-rise buildings. However, it was confirmed that the cable-concrete joint design requires consideration of
the cable initial pre-tension according to the facade load conditions. |