Title |
The Simulation of Irradiation Using the Trouble Factor |
Abstract |
This study is to make analysis of the trouble(T) factor of an extincion condition which is the reduction of irradiation in the atmosphere and to correct the errors between the analyses of irradiation forecasts and the measured amounts of irradiation in the four local areas of Korea. The results of comparative analyses are as follows;1. It was revealed that the extincion T factors of the four areas being measured by sampling were roughly in the ranges of 2 to 4.2. The error between the measured irradiations and the simulated was less than 3% which accounted for a relatively accurate analytical technique.3. Ratio of the direct beam and the diffuse beam of the four areas was approximately 6 to 4. The T factors resulted the aforementioned study could be effectively applicable not only to forecasting the irradiation simulation in the zones other than the four areas but also to the other solar energy-using systems. |