Title |
Performances Comparison of Interleaved Converter for Distributed Power System |
Abstract |
This paper compared to the operation performance and efficiency of an interleaved active clamp ZVS forward converter and an interleaved ZVS half-bridge converter in distributed power system. The design for the current-mode control circuit of an interleaved active clamp ZVS forward converter is presented. To simplify the gate chive circuits, N-P MOSPETs coupled active clamp method is proposed. An efficiency about 90% for the 50~100% load range is achieved. |