Title Development of Electronic Limit Switch for the Drive Unit of Incore Detector System Application
Authors Jong-Beom Park ; Seung-Kwon Yang ; Sang-Hyo Lee
Page pp.1-7
ISSN 1225-1135
Abstract In this paper, we study a cause of malfunction of switch to control drive motor in DFMS(Digital Flux Mapping System) which can measure incore neutron flux of the nuclear plant, and develope a method to solve this problem. DFMS has the type of generating contact signal by mechanical switch lever, which is operated whenever thimble detector inserted or withdrawed through thimble Guide Tube. However the characteristics of the lever tend to be changed by mechanical degrade or bad environment and the lever finally generates errotic contact signal. Therefore we installed electric coil ass"y in the outside of Guide Tube instead of mechanical switch ass"y. In addition, we applied resonance effect to control circuit and installed condenser in the input of power supply to protect noise and interference. After completion of this improvement, we tested this improved device repetitively under the various conditions. In conclusion, we identified the generation of the desired contact signal and the prevention of detector failure through plant surveillance test during normal plant operation.