Title |
The effect of magnet fields on the corona discharge |
Authors |
Jae-yoon Park ; Jang-gun Jung ; Ick-kewn Kim |
Abstract |
In this paper, the effect of magnetic field on corona discharge phenomena was experimentally investigated in the needle-plate electrode geometry. Needle-plate geometry discharge system with magnetic field at a right angle to the electric field was made. The corona discharge characteristics with magnetic field were investigated and compared with the corona characteristics without magnetic field in atmospheric pressure. As a result, in case of positive DC corona discharge with magnetic field, corona discharge zone was significantly wider, corona current was lower, and breakdown voltage was higher than those without magnetic field. However, in case of negative DC corona discharge with magnetic field, corona current was slightly higher and breakdown voltage was lower than those without magnetic field. It is thought that this result is due to cyclotron motion of charged particles such as electron and ion by magnetic field. |