Title |
Measurement of Fluorescence Signal Strength of NO Particle Using ICCD |
Authors |
Yong-Woo Jun ; Won-Zoo Park ; Kwang-Sik Lee ; Hong-Sik Lee |
Abstract |
In this paper, the discharge image of NO particles wire-cylinder type electrode in the discharge reactor where AC dielectric barrier type corona discharge occurred and horizontal and vertical signal intensity at each flourescence emission during discharge and the horizontal and vertical signal strength of NO particles at flourescence emission wavelength band[236[nm], 247[nm], 259[nm]] were measured by ICCD Camera. In addition, discharge images and signal intensities in accordance with discharge time were measured to figure out the discharge mechanism. It was found that the strongest horizontal and vertical signal intensity of NO particles were observed at 247[nm] band, but no big difference in the horizontal and vertical signal intensity in accordance with discharge time was seen. In particular, the phenomenon image occuring inside the discharge reactor and wavelength were able to be compared based on the measured data. |