Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Title AC Breakdown Characteristics of Pure Ar , N2 Gas and Ar / N2 Gas Mixtures under Uniform and Non - Uniform Fields
Authors Sang-Woo Lee ; In-Sik Kim ; Dong-In Lee ; kwang-Sik Lee ; Lee-Kook Kim0
Page pp.20-27
ISSN 1225-1135
Abstract In this paper, the AC breakdown characteristics of pure Ar and N₂ gas with gas pressure range of 58.8~137.3[㎪] under uniform and non-uniform fields were investigated, and the measured values were compared with those in Ar/N₂ gas mixtures with pressure varying. Summarizing the experimental results, the breakdown voltages of pure N₂ gas, under uniform and non-uniform fields, were increased about 4.8 and 1.1 times than those of pure Ar gas, and the AC breakdown voltage increased with the pressure increasing. The breakdown voltages of Ar/N₂ gas mixtures were decreased with decreasing the mixture ratio of N₂ gas. In case of Ar(85%)/N₂(15%) and Ar(70%)/N2(30%) gas mixtures comparing to the pure Ar gas, the breakdown voltages under uniform field were increased about 1.5 and 2.1 times, and under non-uniform field were increased about 1.1 and 1.3 times at the pressure of 101.3[㎪]. Also, corona inception voltage of Ar(70%)/N2(30%) gas mixtures under non-uniform fields were increased about 1.5 times than those of pure Ar gas.