Title Measurement and Analysis of Magnetic Fields and Induced Voltages Caused by Home Appliances
Authors Bok-Hee Lee ; Dong-Moon Lee ; Young-Tae Jang, Keun-Chul Chang ; Ju-Hong Eom ; Sung-Man Kang ; Seung-Chil Lee ; Jung-Wung Park
Page pp.51-59
ISSN 1225-1135
Abstract This paper deals with the measurement and analysis of the induced voltages and magnetic fields caused by the operation of home appliances. The induced voltage and magnetic field measurement circuit used in this work consists of the induction coil, the operational preamplifier and the active integrator. Television set and monitors for personal computer cause strong magnetic fields rich in harmonics and high induced voltages by using the switching power suppliers. The strong magnetic field intensity and high induced voltage were created by 14″television set, and their values are 2.1 [μTp-p] and 140 [mVp-p] at the distance of 0.4 [m], respectively. However, the induced voltage per unit magnetic field intensity was created by 17″monitor for personal computer and the measured data was approximately 560 [mV/μT] at the same distance.