Title The Ozone Generation and Discharge Noise Characteristics of Superposed Discharge Type Ozonizer Using Three-Phase Voltage
Authors Byung-Joon Chun ; Hyun-Jig Song ; Yeong-Hun Kim ; Sang-Tae Choi? ; Kwang-Sik Lee
Page pp.59-67
ISSN 1225-1135
Abstract In this paper, an ozonizer, which can supply individual and superposed silent discharge using three-phase voltage has been designed and manufactured. The ozonizer consists of 3 electrodes( Central Electrode, Internal Electrode and External Electrode ) and 2 gaps( gap between Central Electrode and Internal Electrode, gap between Internal Electrode and External Electrode ). Ozone is generated according to voltage supplying method to each electrode by individual silent discharge and three-phase superposed discharge. The characteristics of ozone generation were investigated with variation of discharge power and the flow rate of supplied gas( 0₂ ). In case of individual silent discharge, the maximum values of ozone concentration, ozone generation and ozone yield were obtained between internal electrode and external electrode, and its values were 2300[ppm], 570[mg/h] and 745[g/kWh] respectively. Each maximum value was 5039[ppm], 1773[mg/h] and 851[g/kWh] respectively, when three-phase superposed silent discharge was employed. Therefore, characteristics of ozone generation with three-phase voltage are improved compared with single-phase voltage because silent discharge is generated continuously.