Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Title Illuminance Distribution Analysis by Lighting Tower Position of a Soccer Stadium
Authors Hong-Kyu Choi ; Byung-Sook Choi ; Kil-Young Kim
Page pp.1-8
ISSN 1225-1135
Keywords illuminance levels for artificial lighting for a player ; changing lighting tower positions ; optimum illuminance distribution ; uboptimal lighting ; horizontal illuminance ; vertical illuminance ; uniformity glare ; stadium
Abstract Nowadays the soccer becomes one of the best spot lighting sports in the world. Especially the 2002 Korea-Japan World Cup was deeply impressed on all the korean. One goal of illuminating engineering should be the design of lighting system that can provide consistently high task visibility regardless of where a task might be located within a working space. The television broadcasting on the soccer has been an important role in the media. The standard of FIFA(The Federation Internationale de Football Association) requires recommended illuminance levels for artificial lighting for a player, an audience, TV broadcasting, as well as everybody in the stadium. This paper has proposed an algorithm to select the suboptimal lighting tower position for watching and TV broadcasting a soccer game within a pleasant environment and an optimum illuminance distribution. The position using the software Philip`s Calculux was chosen based an the calculations of a horizontal illuminance, vertical illuminance, uniformity, glare, and so on by changing lighting tower positions.