Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Title Characteristics of Non-thermal Plasma Generation by Duty Ratio and Frequency of Pulse Voltage
Authors Seung-Lok Park ; Jin-Gyu Kim
Page pp.146-150
ISSN 1225-1135
Keywords Duty Ratio ; Frequency ; Surface and Silent Discharge ; Non-thermal Plasma ; Ozone Generation
Abstract The effects on non-thermal plasma generation by duty Ratio and frequency of pulse voltage were investigated experimentally. For these, a new type of non-thermal plasma generator with mesh electrode was manufactured and it was possible to generate the surface and silent discharge simultaneously by new type of non-thermal plasma generator. Duty ratio and frequency were selected as main parameters to control the movement of electron which is mainly related to the non-thermal plasma generation. The characteristics of non-thermal plasma generation were investigated indirectly by measuring the I-V curve and quantity of ozone generation. The most effective condition of duty ratio and frequency to generate the non-thermal plasma was identified by experiments with manufactured non-thermal plasma generator.