Title |
Actual Conditions on the Illumination Environment of the Study Rooms in the Detached House |
Keywords |
study room ; illumination environment |
Abstract |
In this study, we investigated the actual conditions of illumination environment of study rooms in detached houses. From the results, fluorescent lamp as a lighting source and direct lighting method were mainly used. The additional use of local lighting was 48.2[%], and it was not efficient for detailed work. The average illuminance of general lighting and local lighting were 131.41[㏓] and 322.57[㏓],respectively, and these level were only 54[%] of the lowest illumination standard. This indicates that the lighting levels and the environment are so poor. The satisfaction level of users, however, was relatively high, suggesting insufficient recognition of importancy of lighting for efficient work. |