Title |
Malfunction Measures and Susceptibility test of Elevator Based on EMS(Electromagnetic Susceptibility) Standard |
Authors |
Gi-Hyun Kim ; Suk-Myong Bae ; Joo-Hwan Lee |
Keywords |
Elevator ; Power Quality ; EMS ; ESD ; Surge ; Malfunction |
Abstract |
The malfunction accidents such as kept within elevator, sudden rise, sudden stop, error of level indication which can bring about uneasiness of elevator passenger and be related with life accident are occurring. However, as there is not field recurrence for this portion and they are accidents that occur and then disappear, it is actually difficult to confirm the reason of accident. Therefore, we made an experiment for tolerance in three models which is being built recently according to EN12016(2004) standard and analyzed the movement characteristics of elevator to study the reason which can bring about confine and malfunction. Furthermore, after supplementing measures for malfunction, Finally this paper will be used as reference to suggest methods for malfunction of elevator facility and the analysis for mutual relation between Power Quality and malfunction and fault of elevator. |