Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Authors In-Hye Yu ; Hyun-Tae Ahn ; Jeong Tal Kim
Page pp.1-10
ISSN 1225-1135
Keywords Sky Simulator ; Artificial Sky ; CIE Standard Overcast Sky ; Luminance Distribution
Abstract KH University has developed a large sky simulator which is its scale suits international standard. To verify the reliability of the sky simulator, the luminance of 36 points on the inner sky surface was measured and compared with the CIE standard overcast sky model. It was found that the sky simulator can reproduce the CIE standard overcast sky condition with 1.8[%] of mean difference. To identify the differences of daylighting performance, scale model measurements were taken under a real sky and in a sky simulator. Under overcast sky conditions, two kinds of scale model experiments were conducted by using the photometric sensor Li-cor. Firstly, a 1/20 scale model of a side-lit office room 4.9[m] wide, 7.2[m] long, and 2.6[m] high was created Five measurement points were set at 1.2[m], 2.4[m], 3.6[m], 4.8[m], and 6.0[m] from the window. The mean difference of the light factor between the sky simulator and real sky was 7.1[%]. Secondly, a 1/30 scale model of a top-lit atrium 15[m] wide, 15[m] long, and 15[m] high was created. The measurement point was set at center of the room and the well indexes of the model were set in 5 types. The mean difference of the light factor between the sky simulator and real sky was 1.7[%]. This proved that the sky simulator is fully accurate and usable for daylighting research.