Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Title The Protective Countermeasure of Water Purifier PCB according to Abnormal Voltage
Authors Dong-Ook Kim ; Chung-Seog Choi ; Hyun-Wook Moon ; Ki-Yeon Lee ; Hyang-Kon Kim
Page pp.64-70
ISSN 1225-1135
Keywords Abnormal voltage ; Power control system ; Electrical safety ; Insulation blackdown
Abstract The electrical accident results from an insulation blackdown by over-voltage, an overheating by the excess of allowable current, a deterioration performance by the passage of time, and so on. This paper discusses how to improve the power control system of PCB in water purifier. The protecting device of present power supply control system in water purifier is composed of the varistor device which acts only for impulse-type surges. So the present system can not be protected others except the surge of impulse-type. The newly-suggested power control system in this paper is designed to protect the system by disconnecting power supply through SSR(Solid State Relay) if the value of input voltage is exceeded the setting value.