Authors |
Dong-Cheol Jeong ; Cheol-Hee Moon |
Keywords |
AC PDP ; dynamic false contour noise ; decay time |
Abstract |
The dynamic false contour noise was analyzed with consideration for the phosphor decay time of an ac PDP by computer simulation based on the measurement of the 1/10 phosphor decay times of the primary colors red green and blue at the main wavelengths of each phosphor. The noise level of dynamic false contour is strongly dependent on phosphor decay time. The noise level decreases incrementally with the phosphor decay time whereas the noise width increases. The moving velocity of an object does not affect the noise level. The entire experiment was performed under the condition of 8 subfields ADS driving scheme, 2.5[μsec] scan speed, and 5 [μsec] sustain period with VGA grade panel. |