Authors |
Sang-Pil Mun ; Chil-Ryong Kim ; Jong-Kurl Lee ; Hong-Sin Kim ; Sang-Hwa Jung ; Soon-Kurl Kwon |
Keywords |
ZCS PWM ; Induction Heating(IH) ; Induction heating apparatus ; Asymmetncal pulse width modulating control |
Abstract |
This research presents a new active auxiliary resonant snubber with for induction heating PWM high frequency inverter solving the problem of induction heating PWM high frequency inverter circuit which is using widely in the practical application of an induction heating apparatus, the soft switching operation and power control are impossible when the lowest power supply in the active auxiliary resonant snubber with for induction heating PWM high frequency inverter. The inverter circuit which is attempted by the on-off operation of a switch has the effect of reducing the power loss due to soft switching and high frequency switching. This confirms that power regulation is possible on a continuous basis from 0.25[kW] to 2.84[kW] where the duty factor (D) changes from 0.08 to 0.3 under zero current switching which operates by an asymmetrical pulse width modulating control. The power conversion efficiency is 95[%]. Due to these results, the active auxiliary resonant snubber for an induction heating PWM high frequency inverter is considered effective as a source of induction heating. |