Title |
An Experiment of Discomfort Glare from Non-uniform Glare Source |
Authors |
Ju-Young Shin ; Jeong-Tai Kim ; Won-Woo Kim |
Keywords |
Glare ; Discomfort Glare ; Luminance ; Luminance contrast |
Abstract |
Impact of daylighting on the visual environment can improve occupant’s well-being by providing visual comfort. Also, daylighting can save energy. However, glare from window can be a direct hazard to vision and can cause serious discomfort. Selecting glare source on a window plane is very important for evaluating discomfort glare from windows. But former glare indices can not identify the range of the glare source properly. In this study, difference in glare sensation with uniform and non-uniform glare sources are evaluated to identify the range of the glare source. The glare source was assumed as 120×120[㎝] window model. The window was divided into three parts with different luminance values. The experiment was conducted under 1[m], 1.5[m], 3[m] distance from the glare source. Two results were obtained from the experiments. First, the degree of discomfort glare increased as average window luminance increased. Second, the middle and lower part of the window plane can affect evaluation of discomfort glare as well as the upper part of the window plan. These results can be used for selecting the glare source in a window with non-uniform luminance. |