Title |
Actual Conditions on the Illumination Environment of the Study Rooms in the Youth of an Agriculture Village |
Authors |
Hyun-Ji Kim ; Kyoung-Sun Jun ; In-Hyo Lee ; Ok-hee An |
Keywords |
Study Room ; llumination Environment |
Abstract |
This study investigated the actual conditions of the illumination environment from agricultural youth study room. The result, average space of the study room was 11.42[㎡]. The illuminant uses the fluorescent lamp mainly, Method of using illumination was only general illumination the case which uses 73.8[%]. Method of light distribution was a direct lighting mainly. The house which has a stand illumination was also 45.7[%], The percentage using the stand illumination which was a local illumination was nothing but in 20[%] of the whole subject of investigation, therefore eye work could not effective. The internal illuminance was average 131.82[lx], the desk illuminance was 253.64[lx] which was the minimum permitted limit and poor. Uniformity ratio of illuminance appeared with average 35.61[%]. The satisfaction with 3.93 points to be high for illumination environment, therefore it was thought that the recognition of illumination was very insufficient. |