Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Title Performance Evaluation of Low Frequency Magnetic Field Shielding by Eddy-Current
Authors Hak-Yun Choi
DOI http://dx.doi.org/10.5207/JIEIE.2010.24.9.124
Page pp.124-128
ISSN 1225-1135
Keywords Eddy-Current ; Magnetic Shielding ; Skin Depth ; Helmholtz Coil ; Magnetic Sensors
Abstract In this paper, the shielding effectiveness of aluminum shielded room with using eddy-current is calculated and measured after fabricated. The size and thickness of shielded room are decided as 2.4 × 2.4 × 2.4[㎥] and 12[㎜] after AC shielding characteristics by eddy-current of conductive materials is analyzed. To verify the shielding effectiveness, a rectangular helmholtz coil is fabricated to generate magnetic field of 1.37[μT] and measured magnetic field inside shielding room for 0.01~10[㎐]. According to calculations and measurements, AC Shielding effectiveness by eddy-current in aluminum is very small for 0.01~2[㎐] and 5 times to 11 times for 5~10[㎐].