Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Title Calculation of CO₂ Emission for Fossil-Fired Thermal Power Plant considering Coal-Oil Mix Rate
Authors Sang-joong Lee ; Soon-Ki Kim
DOI http://dx.doi.org/10.5207/JIEIE.2010.24.10.067
Page pp.67-72
ISSN 1225-1135
Keywords CO₂ Emission Calculation ; Thermal Power Plant ; Coal-Oil Mix Rate
Abstract G8 summit meeting held in July 2008 decided to set up a long-term goal, by 2050, reducing the world greenhouse emissions by half of those emitted in 1990. In November 2009, the Government announced to reduce the national CO₂ emission by 30[%] of BAU by 2020. Electric power industries in Korea produce most of their electricity by burning fossil fuels, and emit approximately 28[%] of national CO₂ emissions. Monitoring the CO₂ emission of electric power plants is very important. This paper presents a method to calculate the hourly CO₂ emission for a thermal power plant burning mixture of coal and oil using the performance test data and coal-oil mix rate. An example of CO₂ emission calculation is also demonstrated.