Title |
Calculation of CO₂ Emission for Fossil-Fired Thermal Power Plant considering Coal-Oil Mix Rate |
Authors |
Sang-joong Lee ; Soon-Ki Kim |
DOI |
http://dx.doi.org/10.5207/JIEIE.2010.24.10.067 |
Keywords |
CO₂ Emission Calculation ; Thermal Power Plant ; Coal-Oil Mix Rate |
Abstract |
G8 summit meeting held in July 2008 decided to set up a long-term goal, by 2050, reducing the world greenhouse emissions by half of those emitted in 1990. In November 2009, the Government announced to reduce the national CO₂ emission by 30[%] of BAU by 2020. Electric power industries in Korea produce most of their electricity by burning fossil fuels, and emit approximately 28[%] of national CO₂ emissions. Monitoring the CO₂ emission of electric power plants is very important. This paper presents a method to calculate the hourly CO₂ emission for a thermal power plant burning mixture of coal and oil using the performance test data and coal-oil mix rate. An example of CO₂ emission calculation is also demonstrated. |