Abstract This paper discussed the theoretical simulation results for developing the blumlein pulsed power source and showed the circuit configuration and the discharge characteristics of the realistic manufactured pulsed power system. In the simulation, the output voltage characteristics at a load resistor showed the general impulse shape when the impedance of a single coaxial cable is matched with the that of a load resistor. In addition, it is confirmed that output values of the pulsed power can be easily controlled by the duplication of coaxial cables and the pulsed waveform showed the general impulse characteristics. Specifically, the inception discharge voltage in the gap distance of 5[㎜] between needle and plane electrodes is about 20[㎸] and which is lower than about 29[㎸] in 9[㎜] due to the difference of the reaching time of the inception voltage. Therefore, this paper showed that the output voltage of the blumlein pulsed power source can be easily controlled.