Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Authors Young-Kwan Choi ; Sang-Yule Choi ; Myong-Chul Shin
DOI http://dx.doi.org/10.5207/JIEIE.2010.24.11.023
Page pp.23-29
ISSN 1225-1135
Keywords Cathodic Protection ; Corrosion Protection Current
Abstract The principal factor determining an optimum design method for cathodic protection is finding the protection current for preventing the corrosion of existing, already laid pipe. Some factors currently used to test designs include the sizes and lengths of pipes, soil resistivity, and the coating damage rate. We believe this method and current formulae are not optimum due to the uncertainty of determining the coating damage rate and the corrosion protection current"s density. This paper analyzes the amount of protection current obtained by performing a temporary current test using data describing existing laid pipe. We then propose determining the corrosion protection current by using the temporary current test after modifying the formula. In addition, we suggest a way to choose optimized cathodic protection and the process of design by executing the design and taking account of such factors as a site condition of 34km-long non-protected water supply pipe lines (stages Ⅰ and Ⅱ) in ○○ region, climate. interferences, and durability.