Title |
The Thermal Characteristics of Partially Disconnected Wire Happened in Plug |
Authors |
Seung-wook Jee ; Shi-Kuk Kim ; Chun-Ha Lee |
DOI |
http://dx.doi.org/10.5207/JIEIE.2011.25.4.104 |
Keywords |
Partially Disconnected Wire ; Electric Fire ; A Rated Current ; Plug |
Abstract |
There are over 30[%] of electric fires in Korea happened at wire or wiring devices. For its prevention many safety devices are set up electric equipments. These safety devices are not working in a rated current"s condition of electric equipment. But when wire is partially disconnected, electric fire is able to be happened even though current is smaller than a rated current value. This paper studied thermal characteristics and fire ability when wire in plug is partially disconnected. The experiment is progressed a method that inner wire of plug is partially disconnected and after that current that is less than a rated current is flowed. As the result, heating occurred in near of partially disconnected wire makes that outer sheath is melted, plug cover is carbonized, and even sometimes wire is fused. And results of analysis of thermal image of partially disconnected wire happened in plug, it shows a difference to heating distribution and temperature appeared surface of plug depend on a progress of a partially disconnected wire. |