Title Measurement and Analysis of Adaptation Luminance in the Threshold Zone of the Road Tunnel
Authors Jong-Sung Han ; Min-Wook Lee ; Hoon Kim
DOI http://dx.doi.org/10.5207/JIEIE.2012.26.1.001
Page pp.1-7
ISSN 1225-1135
Keywords Threshold Luminance ; Adaptation Luminance ; Veiling Luminance Method ; L20 Method
Abstract As the standard lighting required in the threshold zone of a road tunnel is determined by the enough contrast. Lighting design, therefore, must be determined by the calculation method of threshold luminance based on the adaptation luminance of the driver approaching the tunnel. The veiling luminance and the luminance in the access zone were measured at different time and in different weather using the veiling luminance method, a kind of perceived contrast methods, and the L20 method when the range of vision was 20 degrees. On the basis of the measured data each threshold luminance was calculated and its results were analyzed.