Title |
Characteristics of Transient State and Stress of Three-Phase Switched Trans Z-Source DC/AC Power Converter |
Authors |
Young-Cheol Lim ; Se-Jin Kim ; Young-Gook Jung |
DOI |
http://dx.doi.org/10.5207/JIEIE.2012.26.4.057 |
Keywords |
Z-Source DC/AC Inverter(ZSI) ; Switched Trans Cell ; Voltage and Current Stress ; Transient State ; Duty Ratio ; Boost Factor |
Abstract |
When typical Z-source DC/AC inverter(ZSI) is operated in high voltage gain area, because of its high duty ratio, voltage and current stress in Z-network of typical ZSI are increased. This paper proposes a new switched trans ZSI(STZSI) with two switched trans cells which consist of one trans and two diodes. To confirm the operation performance of the proposed system, the PSIM simulation is performed for typical ZSI, switched inductor ZSI and the proposed STZSI. Voltage / current stress and transient state characteristics of each method are compared under the condition of DC input voltage 100[V] and output phase voltage 66[Vrms]. As a result, we confirmed that transient state of the proposed STZSI is short compared with the conventional ZSI because the high voltage gain is obtained using the same duty ratio, also a low duty ratio is required for the same output voltage. Finally, we could know the proposed system have low voltage and current stress in Z-network compared with the conventional ZSI. |