Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Title New Secondary Battery Charger/Discharger Available for Zero Voltage Discharge
Authors Dae-Taek Chung ; Soo-Yong Chae ; Soon-Chan Hong
DOI http://dx.doi.org/10.5207/JIEIE.2012.26.11.062
Page pp.62-74
ISSN 1225-1135
Keywords Secondary Battery ; Zero Voltage Discharge ; Bidirectional Converter
Abstract This paper proposes a new secondary battery charger/discharger available for zero voltage discharge which is used for test equipments and formation process. The proposed system is a switching type converter, and thus the system is high efficiency and more compact as compared with linear type charger/discharger. Conventional switching type charger/discharger can not discharge secondary batteries to zero voltage because of voltage drops in the switching elements and long distributing line(typically 10m). However, the proposed system is able to discharge the battery to zero voltage in constant current mode regardless of the voltage drops. In this paper, we analyze the proposed charger/discharger and the validity of the system is verified by simulation and experiment.