Title |
Calculation of Induced Current in the Human Body by Magnetic Field in the 100kHz~10MHz Resonant WPT Frequency Range and Analysis of EMF Guideline |
Authors |
Han-Su Shin ; Hye-Jin Song ; Jin-Kyu Byun |
DOI |
http://dx.doi.org/10.5207/JIEIE.2013.27.2.110 |
Keywords |
Wireless Power Transfer ; EMF Guideline ; Induced Current ; Quasi-Static FDTD |
Abstract |
As the technologies such as middle-range resonant WPT (wireless power transfer) advance that utilizes medium and low-frequency magnetic field, the importance of safety of such magnetic field is growing. The research on the effect of electromagnetic field on the human body has been mainly done on the GHz range of mobile phones, or 50~60Hz range of electric power systems. However, there has been relatively few works on the 100kHz~10MHz range used in the resonant wireless power transfer. Since there is a difference in the limiting value of magnetic field between widely used ICNIRP EMF guideline and IEEE C95.1 standard, there can be possible confusion when establishing EMF (Electromagnetic Field) standard on the wireless power transfer device in the future. In this paper, the induced current in the human body, which is the basic restriction of the EMF guideline, is calculated using Quasi-static FDTD method when 3D high-resolution human model is exposed to the 100kHz~10MHz magnetic field. Using this result, the feasibility of the magnetic field reference level in the ICNIRP guideline is analyzed. |