Title |
Understanding Governor Droop of Turbine-Generator through Graph and Proportional Expression |
DOI |
http://dx.doi.org/10.5207/JIEIE.2013.27.5.033 |
Keywords |
Droop Setting ; Turbine-Generator Governor ; Generator Load Sharing ; Proportional Expression |
Abstract |
This paper presents a simpler calculation of the generator load sharing according to the change of system frequency and the droop setting of turbine-generator governor. The author firstly draws a graph based on the generator operation at rated MW output and normal frequency, and secondly, builds a proportional expression using the graph in order to obtain the solution in a simpler way rather than using conventional mathematical calculation, to provide the readers with an easier understanding of the droop setting of turbine-generator governor. |