Efficiency and EMF Safety Analysis of Wireless Power Transfer System Using Standard Human Model |
Authors |
Han-Su Shin ; Jin-Kyu Byun |
DOI |
http://dx.doi.org/10.5207/JIEIE.2013.27.11.096 |
Keywords |
Wireless Power Transfer ; Efficiency ; Human Body Safety |
Abstract |
In this paper, resonant wireless power transfer systems are designed with double loop resonant coils for the resonant frequency of 150kHz. The transfer efficiency characteristics is analyzed according to the coil size, and the distance and misalignment between the coils. Then the change in efficiency is investigated when a human model is located between the resonant coils using the homogeneous human phantom of IEC-62311 standard. Also, in order to assess the safety of the wireless power transfer system, the induced current density inside the human model is calculated when it is exposed to the magnetic field of a plane wave and resonant coil. Then, the results are compared with the exposure limits in the EMF (electromagnetic field) safety guidelines. |