Title |
Parameters Estimation Characteristics of Five-Phase Squirrel-Cage Induction Motor within Over Current Load |
DOI |
http://dx.doi.org/10.5207/JIEIE.2015.29.7.038 |
Keywords |
Five-Phase IM ; Equivalent Circuit ; No-Load Test ; Locked Rotor Test ; Variable Over Current Load ; Parameter Estimations |
Abstract |
This paper propose a variable parameter estimations for variable over current load of five-phase squirrel-cage induction motorIM) to servo control system. In order to high performance control of AC motor using a field oriented controlFOC) and direct torque controlDTC) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, torque command of current components, rotor position, speed estimation, and so on. We are suggest a analyzed estimation results of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental within variable over current load at rated input frequency. There are results of stator winding measurement, no-load test, locked-rotor test, variable over current load test, and estimated parameters of equivalent circuits using manufactured experimental apparatus by IEEE Standard Test Procedure for Polyphase Induction Motors and Generators 112-2004. |