Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Title An Improved Switching Technique for Reducing of Ground Voltage in Solar Modules
Authors Sang-Kil Lim ; Byoung-Woo Park ; Seong-Mi Park ; Sung-Jun Park
DOI http://dx.doi.org/10.5207/JIEIE.2016.30.7.092
Page pp.92-99
ISSN 1225-1135
Keywords Inverter ; Ground Detect ; Transformer-Less ; PID Phenomenon ; Voltage to Ground
Abstract Recent solar inverter there is an increasing demand for high efficiency and economy. The alternative can be applied to the transformer-less type grid-connected inverter. In general, transformer-less grid-connected inverter to operate input side solar module connected floating. Due to that ground voltage raises between solar module and ground. As a result, it accelerates the PID(Potential Induced Degradation) phenomenon and thereby causes a risk of electric shock and if not inhibits the efficiency of photovoltaic solar modules. This paper proposed ground detect technique and switching technique which reduce ground voltage between solar modules and ground in transformer-less type grid connected inverter system. The proposed control method and technique was verified through the simulation results and experiment, using the Power SIM.