Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Title A Study on the New Active Clamp Snubber Applied Quasi Resonant Flyback Converter
Authors Kyung-Boo Yu ; Jong-Ok Baek ; Tae-Young Ahn
DOI http://dx.doi.org/10.5207/JIEIE.2017.31.1.042
Page pp.42-48
ISSN 1225-1135
Keywords RCD Snubber ; Active Clamp Switching ; Quasi Resonant Flyback ; Lossless Active Snubber
Abstract In this paper, active clamp snubber method was proposed to reduce effectively the switching surge voltage of the conventional quasi resonant(QR) flyback converter. The usefulness and practicality of the proposed method in QR flyback converter were verified through steady state analysis and its experimental results. The performance of the proposed circuit was compared with the RCD snubber method. It was verified from the experimental results that the switch peak voltage of the proposed method was limited below 5% while the switch peak voltage of the RCD snubber was continuously increasing accordingly with the load current. Furthermore, this new active clamp snubber method could be applied to QR flyback and its power conversion efficiency was superior to the RCD snubber one.