Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Title A Study on the Negative Supplying Voltage for Floating Switches using Charge Pump Capacitor with Bootstrap Circuitry
Authors Joung-Hwan Bae ; Jong-Mu Lee ; Chung-Yuen Won
DOI http://dx.doi.org/10.5207/JIEIE.2017.31.7.077
Page pp.77-83
ISSN 1225-1135
Keywords Bootstrap circuit ; Charge Pump ; Bipolar Gate Drive ; Negative Supplying Voltage
Abstract The unipolar gate driving method provides a low cost and simple solution for inverter system design. However, the unipolar gate driving can cause issues like ‘parasitic oscillation’ during turn-on of power switches and ‘unintended parasitic turn-on’ caused by the Miller-effect of power semiconductors. Hence the maximum value of gate resistance has to be limited. The proposed bootstrap circuit can generate a negative gate voltage with minimal increase of components. For this purpose a charge-pump circuitry is merged with a standard bootstrap topology which can generate a negative as well as a positive gate voltage for floating switches without additional isolated power supply.