Title |
Final Output Data Interpolation Error Improvement for Look-up Table Based PMSM Control Method |
DOI |
http://dx.doi.org/10.5207/JIEIE.2018.32.7.045 |
Keywords |
Look-up table based PMSM drive ; 2D-Interpolation ; Interpolation error |
Abstract |
This paper proposes a novel linear interpolation method for improving final output data interpolation error appliable in look-up table based PMSM drive. Conventional linear interpolation method is generally 2D-Interpolation method which has two input parameters. This 2D-Interpolation method uses constant unit torque for reducing DSP processing time, it has a problem when the interpolation process is performed with final torque output, interpolated output can not follow the torque reference. In this paper, a modified conventional interpolation method is proposed to remove torque control error of final torque output data. |