Mobile QR Code QR CODE : Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

Journal of the Korean Institute of Illuminating and Electrical Installation Engineers

ISO Journal TitleJ Korean Inst. IIIum. Electr. Install. Eng.
Title Study on the Mechanical Stress of Insulators for Application of 25 kV Railway Traction Lines
Authors Eliana Bella ; Minkyung Jeong ; Youngdae An ; Jongdoug Lee ; Hyoungku K ang
DOI http://doi.org/10.5207/JIEIE.2020.34.7.027
Page pp.27-33
ISSN 1225-1135
Keywords Cantilever Load Test; Railway Insulator; Structure Analysis; Tensile Force Test
Abstract In this paper, mechanical stresses on railway traction line insulators are analyzed by structural analysis. In application of railway traction lines, insulators are not only used to insulate but also subjected to adverse environmental conditions and mechanical vibrations. Two kinds of test to verify the robustness of insulators are performed in this study. Cantilever load test and tensile force test are carried out to ensure the reliability and stability of railway traction line insulators. Structural analysis that focuses on cantilever load test and tensile force test is carried out by using COM