Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)

References

1 
Lee J., Lee S., 2014, Analysis of the inflow characteristics of fine dust (PM10) using WRF-Chem, Proceedings of the Autumn Meeting of KMS, Vol. 2014, No. 10, pp. 898-899Google Search
2 
Park S., Shin H., 2017, Analysis of the Factors Influencing PM2.5 in Korea : Focusing on Seasonal Factors, Journal of Environmental Policy and Administration, Vol. 25, No. 1, pp. 227-248Google Search
3 
Park C., 2016, Air purifier market and technology trends, Journal of Korea Institute of Architectural Sustainable Environment and Building Systems, Building environment facilities, Vol. 10, No. 1, pp. 7-11Google Search
4 
Logue J., McKone T., Sherman M., Singer B., 2011, Hazard assessment of chemical air contaminants measured in residences, Indoor air, Vol. 21, No. 2, pp. 92-109DOI
5 
Shaughnessy R., Sextro R., 2006, What is an effective portable air cleaning device? A review, Journal of Occupational and Environmental Hygiene, Vol. 3, No. 4, pp. 169-181DOI
6 
Letourneau P., Mulcey P., Vendel J., 1991, Aerosol penetration inside HEPA filtration mediaGoogle Search
7 
Wang H.-C., Kasper G., 1991, Filtration efficiency of nanometer-size aerosol particles, Journal of Aerosol Science, Vol. 22, No. 1, pp. 31-41DOI
8 
Spielman L., Goren S. L., 1968, Model for predicting pressure drop and filtration efficiency in fibrous media, Environmental Science & Technology, Vol. 2, No. 4, pp. 279-287DOI
9 
Payet S., Boulaud D., Madelaine G., Renoux A., 1992, Penetration and pressure drop of a HEPA filter during loading with submicron liquid particles, Journal of Aerosol Science, Vol. 23, No. 7, pp. 723-735DOI
10 
Kwon M., Jang S., Ryu J., Seo S., Won S., Jung S., 2009, A study on management of major indoor air pollutants by house type in Korea (I) : indoor air pollution and health effects in residential apartment, Incheon, National Institute of Environmental Research, pp. 66Google Search
11 
Wang J., Chen D. R., Pui D. Y., 2006, Modeling of filtration efficiency of nanoparticles in standard filter media, in Nanotechnology and Occupational Health, Springer, pp. 109-115DOI
12 
Thomas D., Contal P., Renaudin V., Penicot P., Leclerc D., Vendel J., 1999, Modelling pressure drop in HEPA filters during dynamic filtration, Journal of Aerosol Science, Vol. 30, No. 2, pp. 235-246DOI
13 
MacIntosh D. L., Myatt T. A., Ludwig J. F., Baker B. J., Suh H. H., Spengler J. D., 2008, Whole house particle removal and clean air delivery rates for in-duct and portable ventilation systems, Journal of the Air & Waste Management Association, Vol. 58, No. 11, pp. 1474-1482DOI
14 
Calle S., Contal P., Thomas D., Bémer D., Leclerc D., 2002, Evolutions of efficiency and pressure drop of filter media during clogging and cleaning cycles, Powder Technology, Vol. 128, No. 2-3, pp. 213-217DOI
15 
SPS-KACA002-132, Indoor Air Cleaners, 2006, Korea Air Cleaning AssociationGoogle Search
16 
EN 1822 : High efficiency particulate air filters (HEPA and ULPA), Beuth Verlag GmbH, Berlin, Germany (1998/ 2001) Part 1-5Google Search
17 
12103-1., I., Test dust for filter evaluation, Part 1 : Arizona Test Dust, 1997, International Organization for Standardization (ISO) Geneva, Switzerland.Google Search
18 
JIS Z. , 1995, 8901(1995), Test Powders and Test Particles, Tokyo : Japanese Standards Association.Google Search
19 
ASHRAE Handbook : Fundamentals , 2000, American Society of Heating, Refrigerating and Air-Conditioning Engineers.
20 
Korean Standards, , 2001, KS B6311,, Testing methods for industrial fans.Google Search