Mobile QR Code QR CODE : Korean Journal of Air-Conditioning and Refrigeration Engineering
Korean Journal of Air-Conditioning and Refrigeration Engineering

Korean Journal of Air-Conditioning and Refrigeration Engineering

ISO Journal TitleKorean J. Air-Cond. Refrig. Eng.
  • Open Access, Monthly
Open Access Monthly
  • ISSN : 1229-6422 (Print)
  • ISSN : 2465-7611 (Online)

References

1 
Hwang S. H., Seo S., Yoo Y., Kim K. Y., Choung J. T., Park W. M., 2017, Indoor Air Quality of Daycare Centers in Seoul, Korea, Building and Environment, Vol. 124, No. , pp. 186-193DOI
2 
Branco P. T. B. S., Alvim-Ferraz M. C. M., Martins F. G., Sousa S. I. V., 2015, Children’s Exposure to Indoor Air in Urban Nurseries-Part I : CO2 and Comfort Assessment, Environmental Research, Vol. 140, No. , pp. 1-9DOI
3 
Tezara C., Adam N. M., Juliana J., Mariani M., Siregar J. P., 2014, Monitoring of the Indoor Air Quality Parameters in the Day-Care Centers in Tropical Country, International Journal of Mechanical Engineering(LJME), Vol. 3, No. 1, pp. 47-52DOI
4 
Zuraimi M. S., Tham K. W., Chew F. T., Ooi P. L., 2007, The Effect of Ventilation Strategies of Child Care Centers on Indoor Air Quality and Respiratory Health of Children in Singapore, Indoor air, Vol. 17, No. 4, pp. 317-327DOI
5 
Fairchok M. P., Martin E. T., Chambers S., Kuypers J., Behrens M., Braun L. E., Englund J. A., 2010, Epidemiology of Viral Respiratory Tract Infections in a Prospective Cohort of Infants and Toddlers Attending Daycare, Journal of Clinical Virology, Vol. 49, No. 1, pp. 16-20DOI
6 
Hernandez S. F., Morales H. R., Cuevas R. P., Gallardo H. G., 1999, The Day Care as a Risk Factor for Acute Respiratory Infections, Arch. Med. Res., Vol. 30, No. 23, pp. 216-223DOI
7 
Jaakkola J. J. K., 2000, Day-Care Centers and Health, In : Spengler, J. D., Samet, J. M., McCarthy, J .F. (eds) Indoor Air Quality Handbook, 69.1-69.20, New York, McGraw-HillGoogle Search
8 
Shin N., Ahn J., 2012, Factors Affecting the Number of Hours Children Spent in Child Care Centers Among Dual-Working Families, Korea Journal of Human Ecology, Vol. 21, No. 5, pp. 863-874DOI
9 
Korea Ministry of Environment , 2019, A Study on the Detailed Implementation of the Particulate Matter Concentrated Management Area Designation SystemGoogle Search
10 
Kang D., Choi D., 2015, A Preliminary Study to Evaluate the Impact of Outdoor Dust on Indoor Air by Measuring Indoor/Outdoor Particle Concentration in a Residential Housing Unit, J. KIAEBS, Vol. 9, No. , pp. 462-469DOI
11 
Park J. S., Jee N. Y., Jeong J. W., 2014, Effects of Types of Ventilation System on Indoor Particle Concentrations in Residential Buildings, Indoor Air, Vol. 24, No. 6, pp. 629-638DOI
12 
Mullen N. A., Liu C., Zhang Y., Wang S., Nazaroff W. W., 2011, Ultrafine Particle Concentrations and Exposures in Four High-Rise Beijing Apartments, Atmospheric Environment, Vol. 45, No. 40, pp. 7574-7582DOI
13 
He C., Morawska L., Hitchins J., Gilbert D., 2004, Contribution from Indoor Sources to Particle Number and Mass Concentrations in Residential Houses, Atmospheric Environment, Vol. 38, No. 21, pp. 3405-3415DOI
14 
Morawska L., Salthammer T., 2006, Indoor Environment : Airborne Particles and Settled Dust, John Wiley & Sons, Weinheim, pp. 35Google Search
15 
Um C. Y., Zhang N., Kang K. M., Kim T. Y., 2019, Analysis of Particulate Matter Concentration of Daycare Center by Rooms and Activities, Proceedings of the Architectural Institute of Korea, Vol. 39, No. 2, pp. 347-348DOI
16 
Henry C., Minier J. P., 2014, Progress in Particle Resuspension from Rough Surfaces by Turbulent Flows, Progress in Energy and Combustion Science, Vol. 45, No. , pp. 1-53DOI
17 
Walton G. N., 1989, AIRNET-A Computer Program for Building Airflow Network Modeling, National Institute of Standard and Technology(NIST), USA, Vol. , No. , pp. -DOI
18 
Bae S. H., Lee B. K., Hong C. H., 2004, A Research on the Actual Condition of the Leackage Area of the Building Elements, Proceedings of the KIFSE, Vol. , No. , pp. -DOI
19 
Jo J. H., 2005, Simulation of Pressure Distribution and Solving the Pressure Differentials Problem in High-Rise Residential Buildings, Journal of the Architectural Institute of Korea Planning and Design, Vol. 21, No. 11, pp. 269-276DOI
20 
Tamura G. T., 1994, Smoke Movement and Control in High-Rise Buildings, National Fire Protection Association, Vol. , No. , pp. -DOI
21 
Pedersen C. O., Fisher D. E., Spitler J. D., Liesen R. J., 1998, Cooling and Heating Load Calculation Principles, ASHRAE(American Society of Heating, Refrigerating, and Air-Conditioning Engineers), Vol. , No. , pp. 131-152DOI
22 
Koo B. K., Jeong J. W., Kim J. W., 2020, Elementary School Air Purification Equipment Application Status and On-Site Performance Evaluation, Proceedings of the Architectural Institute of Korea, Vol. 40, No. 1, pp. 322-323DOI
23 
Han B. W., Kang J. S., Kim H. J., Kim Y. J., Won H. S., 2013, Analysis on Particle Cleaning Capacity of Indoor Air Cleaners for Different Flow Rates Considering Energy Consumption, Particle and Aerosol Research, Vol. 9, No. 3, pp. 139-147DOI
24 
Wang X., Gao Z., Yang J., Yang X., 2019, In Situ Investigation on Linkage between Particle Penetration and Air Exchange through Building Envelope, International Journal of Ventilation, Vol. 18, No. 4, pp. 233-245DOI
25 
Kim S. G., Kang D. H., 2018, Analysis on Impact of Outdoor Particle Penetration on Classroom air Quality through Estimation of Particle Penetration Coefficient and Deposition Rate, Proceedings of the Architectural Institute of Korea, Vol. 38, No. 1, pp. 388-389DOI
26 
Ferro A. R., Kopperud R. J., Hildemann L. M., 2004, Source Strengths for Indoor Human Activities that Resuspend Particulate Matter, Environmental Science & Technology, Vol. 38, No. 6, pp. 1759-1764DOI