Title |
Analysis of Lighting and Ventilation Performance in the Remodeling Floor Plan of Aged Apartment |
Authors |
최재필(Choi, Jaepil) ; 최준호(Choi, Junho) ; 백수연(Baek, Sooyeon) ; 염수(Lian, Shuai) ; 김정우(Kim, Jungwoo) |
DOI |
https://doi.org/10.5659/JAIK.2020.36.11.129 |
Keywords |
Aged Apartment; Remodeling; Lighting; Ventilation; Environmental Performance |
Abstract |
The purpose of this study is to quantitatively analyze the lighting and ventilation performance of a 2-bay type of remodeling unit plan, and
to propose lessons for improving environmental performance. For the data for analysis, three remodeling unit plans were applied. The
methodology of the study adopted a method that allows lighting and ventilation to be quantitative. For the lighting analysis, a methodology
to derive the LEED standard sDA index was applied, and the ventilation analysis was to analyze the natural ventilation performance in the
complex and unit plan through the CFD analysis program as an AOA index. The results of the study are as follows. The lighting
performance is expected to show similar lighting performance to the existing floor plan through the remodeling planning. In terms of
ventilation, performance is expected to decrease in some areas, but performance is expected to improve through window planning adjustment. |